AC Charging Pile Control Principle Analysis

The CP line in an AC charging pile is used to monitor the interaction between the charging pile and the electric vehicle. Based on the location of CP signal generation and detection, it is divided into four modes.

Currently, charging piles generally use mode 3, where the charging pile provides CP signal generation and detection to detect and control the charging status. Based on the connection status between the charging gun and the pile or electric vehicle, there are three connection methods: A, B, and C. The widely used connection method C involves fixing the charging cable to the charging pile and connecting it to the electric vehicle via a charging plug. In this mode, the charging pile needs to determine the charging gun status through the CP signal.

building AC charging piles

The CP signal has two states: DC output and PWM output, with the PWM period being 1kHz. Based on the voltage level, there are three states: 12V, 9V, and 6V. DC/PWM 12V, DC/PWM 9V, and DC/PWM 6V represent three states: the charging plug is not inserted into the electric vehicle socket, the charging plug is inserted into the electric vehicle socket, and the electric vehicle is ready and requesting AC output, respectively. Charging stations need to recognize the above CP signal voltage states to determine the charging behavior status.

To ensure the battery can be charged 800-1000 times, the charging rate should typically be between 0.5°C and 0.25°C. Powered by the national grid, using the onboard charger to charge the battery is a slow charging solution, and the corresponding public facilities are all AC charging stations.

To handle emergencies, it is desirable to charge the battery to 80% of its maximum capacity within 15-30 minutes. The corresponding charging rate should be between 2C and 4C, which is a fast charging solution, and the corresponding public facilities are DC charging stations. DC charging stations are more damaging to the battery, increasing the cost of battery replacement for vehicle owners. Therefore, unless it is an emergency, the use of DC charging stations should be minimized.

Interface technology of AC charging piles

The principles of charging piles in China and abroad are largely similar, but their appearances differ slightly, as follows: AC charging piles charge batteries through an onboard charger. Compared to DC charging piles, AC charging piles are lower in cost, simpler in structure, and more battery-friendly, making them suitable for widespread adoption. The following section will introduce the interface technology of AC charging piles from basic to advanced levels.

The main function of AC charging piles (including standard and non-standard models) is to extract single-phase or three-phase power. The charging pile only acts as a current relay station; subsequent rectification and DC/DC conversion are completed by the onboard charger.

Standard AC charging piles are based on the original AC charging pile but add some commercial modules (such as a human-machine interface, billing module, alarm module, etc.) and control and guidance circuits. The control and guidance circuit is the core of AC charging pile interface technology. To be compatible with single-phase and three-phase power, the national standard AC charging pile interface ultimately adopts a 7-terminal structure, and its terminal distribution is shown in the figure below:

Typical control and guidance circuit diagram for charging mode 3 connection method B
Typical control and guidance circuit diagram for charging mode 3 connection method B

Typical control and guidance circuit diagram for charging mode 3 connection method B: The main function of the control and guidance circuit is to confirm whether the charging interface and charging socket are connected, and then to perform periodic checks during the charging process to determine whether to continue charging or stop charging.