During the charging phase, the vehicle closes K5 and K6, and the charging pile closes K1 and K2.

Interactive BCS, BCL, and CCS Messages
- BCS message information includes the charging voltage, charging current, maximum single-cell voltage, SOC, and estimated remaining time for the battery pack. If this message is not received at the charging station for more than 5 seconds, charging should be terminated immediately.
- BCL message information includes voltage requirement, current requirement, and charging mode. If this message is not received at the charging station for more than 1 second, charging should be terminated immediately. Under normal circumstances, the voltage requirement should be greater than the “current battery voltage of the vehicle’s power battery” in the BCP message, but less than or equal to the vehicle’s maximum allowable total charging voltage. Failure modes have occurred in the market where the voltage requirement in the BCL message is less than or equal to the “current battery voltage of the vehicle’s power battery.” In this case, there is no current output. Furthermore, there have been cases where the battery voltage exceeds the vehicle’s maximum allowable total charging voltage. As the SOC increases, the vehicle’s battery voltage gradually increases; for example, if the maximum allowable total charging voltage is 450V, during charging, as the SOC increases, the battery voltage of some vehicles exceeds the maximum allowable total charging voltage, which can also lead to a sudden lack of current.
- The CCS message includes the charging module’s output voltage, output current, cumulative charging time, and whether charging is allowed or paused. If the BMS does not receive this message for more than 1 second, charging should be terminated immediately.
These three types of messages contain very important, commonly used parameters and commands.
Charging Module Responds to Voltage and Current Demands
After receiving the voltage and current demands from the BCL message, the charging pile controller forwards them to the charging module. The control of the charging module’s output voltage and current is achieved through typical negative feedback. How the charging module responds to voltage and current demands, and how it determines whether to operate in constant voltage or constant current mode, is a difficult part to understand for practitioners without a background in control theory; even many engineers who write charging pile controller software haven’t fully grasped it.

The vehicle sends BSM, BMV, BML, and BSP messages.
The BSM message provides the battery status, with the following format: highest single-cell power battery voltage number, highest power battery temperature, highest temperature detection point number, lowest power battery temperature, lowest temperature detection point number, single-cell power battery voltage (too high/too low/normal), SOC (too high/too low/normal), charging current (normal/overcurrent/unreliable), temperature (too high/normal/unreliable), insulation status (normal/abnormal/unreliable), output connector status (normal/abnormal/unreliable), and charging enabled/disabled. BMV, BML, and BSP messages are optional. The BMV message provides the voltage value of each single-cell power battery, the BML message provides the temperature of each single-cell power battery, and the BSP message is a reserved message for the power battery.
Real-time determination of battery and voltage/current status
In the charging sequence flowchart of the 27930, the charging station needs to determine whether the battery status is normal. But how does the charging station determine the battery status based on the BSM? The BSM (Battery Management System) messages mentioned above will indicate situations such as excessive battery voltage, overcurrent, overtemperature, abnormal insulation, and charging prohibition, suggesting that the charging process should not continue.
What judgments does the vehicle make regarding the charging station’s status?
Random, occasional “charging gun tripping” issues during charging often occur because the vehicle determines there is a risk and actively terminates charging. The charging station’s messages mainly consist of CML (Charging Multi-Level Machine) and CCS (Charging Control System). CML provides the charging station’s voltage and current ranges, while CCS provides the current output voltage and current, indicating whether charging is permitted or prohibited. If the vehicle determines that the output voltage and current exceed the battery’s maximum allowable voltage and current, it will naturally terminate charging. If the charging current ripple is too large, some models will report a fault and actively shut down.
The determination of charging termination and the sending of charging termination messages occur during the charging phase, not the charging termination phase. The flowchart shows the conditions for determining charging termination at both the charging station and vehicle end.
What causes occasional “charger tripping” during charging?
The standard distinguishes between the terms “fault” and “error.” For the sake of completeness, these reasons are summarized below. Charger fault reasons distinguish between charger over-temperature faults and internal charger over-temperature faults. In fact, there are many types of charger faults, and the information in the CST alone is insufficient to diagnose some problems.