Common-Mode Noise in Switching Power Supplies

The noise current in switching power supplies, inverters, and PE ground wires may seem insignificant, measuring only microamperes. While this common-mode noise circuit is small, the loop area created by its flow path is often very large, so large that you might not even know where it loops back. Therefore, common-mode noise is much more harmful than differential-mode noise. Even a few microamperes can cause your circuit to fail EMC testing.

What is common-mode noise?

It’s in contrast to differential-mode noise. For example, in a switching power supply, there are two power lines, one positive and one negative. If noise current flows out of the positive terminal and back out of the negative terminal, this is called differential-mode noise. When we use an oscilloscope to measure ripple and noise, these are all differential-mode noise. Another type of noise flows in the same direction on both power lines, but returns through other paths, resulting in the same amplitude and phase on both lines. It goes unnoticed because its path is often hidden and difficult to detect. For example, parasitic capacitance can cause noise to flow through the PE ground line between two points.

What are the dangers of common-mode noise?

It can potentially convert into differential-mode noise, damaging your signal.

Common-mode noise can radiate outward through signal and ground lines, interfering with other circuits. The generation and control of common-mode noise are closely related to circuit grounding. Taking a switching power supply as an example, let’s first ask two questions. If the power supply has a casing, grounding is essential.

  • Question 1: Should the heat sink of a switching power supply be connected to the PE ground?
  • Question 2: Should the output power supply ground (negative terminal) be connected to the PE ground?

Common-Mode Noise

There are experimental videos online that use a battery as a power source to prevent other noise interference. The switching power supply circuit, consisting of three MOSFETs and other components, uses an aluminum plate as a heat sink. Switching power supply circuits involves high-speed switching, high-voltage pulsating currents, and large amounts of noise across a wide frequency spectrum. Some of this noise is transmitted along common-mode paths, with the key component being the parasitic capacitance between the MOSFET circuit and the heat sink. If the heatsink is simply grounded, the parasitic capacitance between the heatsink and D is effectively short-circuited. This reduces the impedance of the common-mode loop, but increases the common-mode current. Therefore, the noise curve seen in Spectrum 1 is 6dB higher than the ungrounded curve. Grounding the circuit’s power ground, or zero-volt reference ground, effectively creates another common-mode path. This path is significantly smaller in area and impedance than the original path. Therefore, most of the common-mode current flows through this loop, reducing the common-mode current in the larger loop, significantly reducing the measured conducted noise. By obtaining the line with the lowest amplitude in the diagram, clamping the power and ground wires with a current probe, and measuring the noise current in both loops, we can confirm the accuracy of the above analysis. Experiments online show that grounding is crucial for reducing common-mode noise, but how you ground it is even more important.