EV charging station service, as well as regular inspection, maintenance, and repair, are critical to drivers’ experience and profitability.
There are two kinds of EV charging stations: AC chargers, which are simple to operate, and DC chargers, which are complex and contain numerous electrical components.
AC charger problem
AC charger problems always lie in the charger’s mainboard and the charging connector.
- Overheating: causing chips to be damaged
- Cannot recognize vehicle, CP not 6V. CP circuit damaged.
- Ground problem and abnormal input voltage. Check if normal, if everything is fine, but still shows these error codes, the problem is that the wire is loose and damaged in the circuit. PCB needs to be replaced.

DC charger problem
Key maintenance steps are as follows:
- Perform routine maintenance, such as fan cleaning and inspection.
- Perform troubleshooting repairs, such as vandalism repairs and software upgrades.
- Maximize EV charging station reliability: Increase uptime through proactive maintenance.
- Follow the manufacturer’s maintenance suggestions and timeline.
- Issue a preventive maintenance plan: monthly, quarterly, and annually.
Possible Issues
- Software/network issues, such as OCPP timeouts and firmware errors.
- Overheating issues, such as high loads and poor ventilation.
- User errors, such as improper connector handling.
- Hardware degradation, such as relays, capacitor failure after 10,000 cycles, screens, cables, and electronics.
Charger Physical Issues
- Cable cuts or is destroyed, for example, insulation failure or vehicle impact.
- Circuit breaker failure, tripping, or cracking.
- Connector damage, including worn pins and cracked housings.
- Vandalism, such as damage to screens, housings, and cables.

Preventative Maintenance
- Monitoring software: Check to analyze errors.
- Cleaning the EV charger, such as removing dirt and dust from ventilators, filters, and connectors.
- User education: Handle connectors once to reduce wear.
- Schedule hardware replacements: relays, cables, and connectors after 10,000 cycles, cable cooling hardware and coolant, screens, etc.