How to detect relay sticking failures?

Relay sticking failures within a battery pack can be categorized into two types: failure to close and failure to disconnect.

The common relay layout within a battery pack is shown in the figure below. It includes three relays: the main positive, main negative, and pre-charge relays. Let’s examine how these three relays are bonded.

Common relay layout diagram in battery pack

Two physical quantities are required for detection: voltage and current. In practice, we determine whether a relay is sticking based on the varying voltage and current readings under different operating scenarios.

Also, the sequence in which the relays are powered on and off can be used to generate different test readings to aid in the determination.

Specific Method:

The residual voltage on the load capacitor can affect the voltage detection results.

The figure below shows four detection points: a, b, c, and d. Point b (the negative battery terminal) serves as the reference for the entire sampling circuit. The sticking detection process is embedded in the vehicle’s power-on and power-off processes.

Relay power on and off sequence diagram
When the vehicle is in the Ready state, the initial voltage of the load capacitor is assumed to be 0V.
  • Step 1: When the relay is not closed, measure the voltages of Uab and Udb to determine whether a main positive or precharge fault exists. If a fault exists, further testing will be terminated.
  • Step 2: If the previous step is successful, close precharge relay K2. The voltages of Uab and Udb can be used to determine whether the precharge circuit is operating normally. The change in Ucb voltage can also be used to determine whether a main negative fault exists.
  • Step 3: If the second step is successful, close main negative relay K3 to activate precharge. Monitor the voltage of Ucb to determine whether K3 is operating normally.
  • Step 4: Close main positive relay K1. After 5 minutes, close precharge relay K2. At this point, the MCU can be consulted to briefly discharge the load capacitor. Simultaneously, monitor the voltage of Udb to determine whether K1 is operating normally.

relays

If a fault is detected at any step during power-up, testing will be terminated, allowing the fault to be located.

The entire power-up process can be summarized as follows:

During the vehicle power-down process, it is only necessary to determine whether the relays can be disconnected normally. Unlike the power-up process, when a fault is detected, further determination of the fault is required.

  • Step 1: Disconnect the main positive and negative relays K1 and K3. However, residual voltage will remain on the load capacitor. If both relays disconnect normally, the voltages Udb and Ucb are as shown in the figure below. However, if Udb equals Uab and Ucb is very low, one of the relays must be stuck, requiring the second step.
  • Step 2: Instruct the MCU to discharge the voltage on the load capacitor. After the discharge is complete, measure Udb and Ucb. If Udb and Ucd are close to the voltages shown in the figure below, it is determined that K1 cannot disconnect normally, but K3 is normal.
  • If Udb and Ucb show very low voltages, it can be determined that K1 is normal, and K3 cannot disconnect normally.
  • If Udb and Ucb are close to the voltages shown in the figure below, it can be determined that both K1 and K3 cannot disconnect normally.

 