How to initially diagnose a charging pile module fault? Generally, the module’s current status is determined by the three indicator lights on the front panel. The module typically displays the following indicator light states: the following are the troubleshooting steps and guidelines for each state.

| Indicator lights | Status | Charging Module Meaning | Bidirectional Module Meaning |
| Run indicator lights | Still On | Normal Operation | Module in Rectification Mode |
| Breathing | CEG Module in MPPT Mode | Grid-connected Inverter: On for 2 seconds, Off for 1 second Off-grid Inverter: On for 1 second, Off for 1 second |
|
| Alarm indicator lights | Still On | AC Input Over/Under Voltage Over Temperature Alarm Bus Voltage Abnormal Other Protection Alarms |
DC/AC Over/Under Voltage Alarm Over Temperature Alarm Bus Voltage Abnormality Overload Other Protection Alarms |
| Flickering | Communication Interruption | Communication Interruption Inverter Overload Operation |
|
| Fault indicator lights | Still On | Output Overvoltage Output Short Circuit Address Conflict Bus Fault Other Fault Alarms |
DC Port Overvoltage DC Port Short Circuit Address Conflict Internal Bus Fault AC Side Overload Protection Off-grid AC Output Undervoltage Other Fault Alarms |
| Flickering | Fan Fault | Fan Fault |
Module Communication Abnormality
Possible Causes:
- Problem with the communication cable pins.
- Bent communication pins on the module terminals.
- Mismatch between module address settings and host computer messages.
- Incorrectly installed a matching resistor on the module.
- Fault in the module’s internal communication circuit.
- Overload operation of the module’s inverter (bidirectional modules only).
Troubleshooting Steps:
Check the communication pins
Remove the module with the flashing yellow light and check if the communication pins are bent (see image below).
If the communication pins are bent, try to straighten them. If they cannot be straightened or are broken, return the module for repair.
Check Module DIP Switches
If the module still malfunctions after being moved to a normal slot, swap the DIP switches of the malfunctioning module and the normal module (as shown in the diagram).
If the malfunction is found to be related to the DIP switches after swapping, it indicates that the module’s DIP switch (address) settings are incompatible with the host computer, causing the module failure.
The host computer settings or the module’s DIP switches (address settings) need to be changed as needed.
AB Swap Method:
Swap the faulty module with a normal module slot, or insert a confirmed normal module into the slot containing the problematic module. If the faulty module returns to normal after being moved to a normal module slot, or if the normal module fails to communicate when moved to the problematic slot, the module problem is confirmed.
Check the CAN bus matching resistor.
Use a multimeter to measure the CAN bus resistance. The resistance should be around 60Ω. If the resistance is 120 ohms or the deviation is too large, it indicates that the matching resistor is installed incorrectly.
The correct installation method for the matching resistor is shown in the diagram below. There is a 120Ω resistor at both ends of the module, and the end leading to the system.

Troubleshooting Guidelines for a Constant Yellow Light
Fault Type: Input Undervoltage, Input Phase Loss, Over-Temperature Protection, Bus Voltage Abnormality
Possible Causes:
- Input Abnormality.
- Airflow Blockage, Abnormal Heat Dissipation.
- Internal Component Failure.
Troubleshooting Guidelines:
Confirm Input Voltage Range
Use a multimeter to measure whether the system input voltage is within the normal range.
Note: The charging module’s input voltage is only AC. For bidirectional modules, it’s necessary to determine whether the current input source is DC/AC before measurement.
Confirm if the Module is an Over-Temperature Alarm
Check if the airflow is blocked and if the inlet and outlet temperatures are abnormal. It is recommended that the customer open the front and rear cabinet doors and let the module stand for a period of time. If the module returns to normal after this period, it indicates an over-temperature alarm, and the heat dissipation needs to be checked.