Some customers who purchase our BlueSky charging stations don’t simply connect them to a three-phase AC power source, but convert DC power to three-phase AC power via an inverter to power the charging station. Alternatively, some customers may directly use DC power, converting it at the charging station, and then charging their vehicles. In this case, it’s necessary to connect our charging station to another control system. The most common Modbus communication function is required.

1. Download the mthings software, and run it after downloading.

2. Use a 485 tool to connect the charging station’s mainboard MCU to a computer. Connect the two cables of the 485 tool to the MCU-J6-6 and MCU-J6-8 sockets on the mainboard, respectively. Plug the other end of the 485 tool into a USB port on the computer.

3. In the app, select the appropriate settings and enable the “Display Messages” feature.

4. Modbus register template, select the serial port, and click “Start Polling.” If communication is normal, you’ll see real-time information from the charging station in the window below.

This information is transmitted in real time to other systems connected to this motherboard, such as the PDU and PCS motherboards. This enables coordinated control of the charging station and other systems.
If you have a project that requires controlling a charging station through another system, or would like to obtain information on the tool described above, please contact us at Blue Sky.