Insulation monitoring of DC charging piles GB/T 18487.1 Core safety functions mandated by national standards. The unbalanced bridge method (time-sharing switching bridge method) relies on the absence of detection blind spots、The advantages of mature circuits and controllable costs make it the mainstream solution for 100V-1500V wide voltage fast charging and overcharging scenarios. The selection of resistors directly determines the withstand voltage capability, measurement accuracy, and full voltage range adaptability of the circuit.

This scheme design is based on the industry common engineering premise: Operational amplifier powered by a single power supply of 5V, with a reference voltage of VREF=2.5V, Reserving a safety margin of 0.2V-4.8V for linear output range, Meet the withstand voltage requirements of 1500V DC safety regulations, Covering the national standard of 100 Ω/V insulation fault threshold detection requirements.
Core preferred resistor selection scheme
To simplify material management, a symmetrical design is adopted, with the following core parameters:
High voltage divider resistor Rps/Rns: Select 66M Ω 0.1% precision, 25ppm/°C low-temperature drift resistor, In engineering, 11 6M Ω 0805 patch resistors are connected in series for implementation, The single voltage divider is only 136V, which meets the rated voltage requirements of surface mount resistors, The single power consumption is much lower than the rated value, meeting the safety and reliability requirements for long-term operation at 1500V high voltage.
Proportional amplification resistor R1/R2:Select 100k Ω 0.1% precision, 10ppm/°C precision metal film resistor. The final proportional coefficient Rf/R ≈ 1/660 fully satisfies the linear output constraint of a wide pressure range.
This scheme can achieve stable operation across the entire voltage range: Under the extreme condition of 1500V, the positive and negative sampling outputs are 0.227V and 4.773V, respectively, Completely within the linear range of the operational amplifier; Adequate output amplitude under 100V low voltage conditions, Ensuring ADC sampling accuracy, it can accurately cover the measurement range of 10k Ω -10M Ω insulation resistance, fully meeting the requirements of national standard warning and fault threshold detection.

Scenario-based alternative solutions and key points of engineering compliance
Flexible adjustment for different scenarios:33M Ω voltage divider resistor can be selected for station scenarios with strong electromagnetic interference + 47kΩ High anti-interference scheme for amplifying resistors;3.3V low-power system can choose 100M Ω voltage divider resistor +Adaptation scheme for 91k Ω amplifying resistor.
Key attention should be paid to the landing of the project: the creepage distance between high-voltage and low-voltage systems should be ≥ 8mm. The sampling switch should use a high-voltage reed relay with a rated voltage of 2000V or above. The operational amplifier should use a precision operational amplifier with a bias current of ≤ 10pA. At the same time, an additional leakage current detection circuit is required as redundant protection to fully meet the mandatory safety requirements of the national standard.