1.Client + SGS Inspection
Between 24 February and 1 March 2025, our customer from the Middle East and an SGS third party visited our EV Charger factory to inspect it before delivery.
2. Customer inspection
Firstly, the customer would like to test “Test Scenarios.” Then, we randomly chose a 120KW model with 2 connectors(CCS combo 1+GB/T). The testing items included [Idle power, Efficiency, Efficiency based on SOC, Connector(loss and voltage drop), and Step Rate Charging]. After a one-day inspection by the customer themselves, all data passed the standard of the customer’s requirements(attached; please see the testing Excel below).


3. Issues to be improved for EV Charging Station
While checking the specification and appearance of the EV Charging pile, the customer also found some issues for us to improve. We are much appreciated that with all these optimizations raised by our customers, our product improved a lot.
Interference
For example, the customer considered that it is hard to connect the input cable from this hole to the copper bar since there is interference.
Our solution is moving the hole forward to make the space big enough for “input cables” to go through.

Loose copper bar
The customer also found a loose fixed place on the input cable copper bar. Think about it, when thick and heavy input cable connect here, it is very dangerous if it is not strong enough to hold input cable.
Our solution is to add 3 insulation pillars here to strengthen it.

Magnetic stickers
Normally, we use plastic stickers to put “CCS1, CCS2, GBT, CHAdeMO, Tesla” on the body of our Charging Pile. However, customers consider that normal sticker is not good enough to withstand the bad weather. So according to requirements from customers, we change it to magnetic stickers for customers to change.

This is an interesting issue, customers require a cover which is not easy for other guys to press out of curiosity. Then, we prepare a strong magnetic cover for our Charging Station.

Light Strip Switch
During testing the consumption of standby status, we found when decoration lights are on, the value is up to 95W. Normally, the standard is <50W. After we turn off the decoration light, the value is 33W.
We will also add a table function for the light strip so that it will turn off during the daytime, and turn on during the right automatically.
4. SGS inspection
Then SGS came to do an official inspection, we also found some minor issues here.
The most noteworthy are under-voltage and overvoltage,
The standard value is 300V Undervoltage threshold and 460V overvoltage threshold. Now, the performance of the power module we use has become better and better, so the actual undervoltage threshold is 260V, and the overvoltage threshold is 530V. The optimizing speed of components is very quick these years, sometimes it is our negligence to update documents timely. The result is that the actual result is better than what we write in the document.

5. Conclusion
After 7 days clients+SGS inspection, the customer feels quite satisfied with our support and effort to optimize everything for the EV Charging Pile. All things we do are to make our Charging Pile better and push the limit of the EV Charger industry.