SLAC technology in PLC communication of charging system

This paper deeply explores the SLAC technology in PLC communication of charging systems and explains its working principle, process, advantages, and application scenarios. As a link management protocol based on power line communication between electric vehicles and charging piles, SLAC evaluates channel quality by exchanging detection signals, negotiates optimal communication parameters, and ensures a stable and efficient charging process.

SLAC technology in PLC communication of charging system

1. Introduction

At present, with the booming development of electric vehicles, charging facilities are an important support, and their performance and stability are directly related to the popularity and user experience of electric vehicles. The PLC (Power Line Communication) communication technology in the charging system has become a key technology for data transmission between charging piles and electric vehicles with its advantages of no need for additional wiring and wide coverage. In PLC communication, SLAC (Signal Level Attenuation Characterization) technology plays a vital role, which ensures the stability and reliability of communication between the car and the pile during the charging process.

2. Overview of SLAC Technology

(1) Definition and Background

SLAC is a link management protocol based on power line communication between electric vehicles (EV) and charging piles (EVSE). The power line was originally designed to transmit electric energy. Its high noise, multipath attenuation, and impedance change characteristics lead to unstable communication quality. During the charging process, the car and the pile need to frequently exchange each other’s parameter information to ensure the stability of the charging process. Therefore, before entering the charging process, it is necessary to confirm the stability and reliability of the PLC connection between the car and the pile through SLAC.

(2) Related standards

DIN SPEC 70121 and ISO 15118 3 both have detailed content about the SLAC protocol. The essence of SLAC is to confirm whether the power line connection between the car and the pile is stable and reliable, so the power line communication standard HomePlug AV is also an important reference document.

3. Working principle and process of SLAC technology

(1) Core architecture

The core architecture of the SLAC protocol can be concisely summarized as a “3+2” model, that is, 3 core required steps and 2 auxiliary optional steps.

(2) Core steps

The vehicle (EV) actively sends SOUND to the pile end: the vehicle end generates a random RunID and broadcasts it through the MME command CM_SLAC_PARM.REQ. The pile end that receives the vehicle end request will respond through the MME command CM_SLAC_PARM.CNF. The response content includes the RunId sent by the vehicle end and the number of sounds it expects. The vehicle end broadcasts the MME command CM_START_ATTEN_CHAR.IND three times to inform the pile end that it is about to send SOUND. The vehicle end broadcasts SOUND through the MME command CM_MNBC_SOUND.IND, where the CNT parameter is used to record the number of times sound is sent. After receiving the command, the PLC chip of the pile end will calculate the average attenuation value of the 58 carrier groups in the SOUND message and send it to the pile end communication controller SECC through CM_ATTEN_PROFILE.IND.

The pile end (EVSE) calculates the average attenuation: After the pile end receives 10 SOUNDs and 10 attenuation values calculated by the PLC chip, it calculates the average attenuation value of these 10 SOUNDs and informs the vehicle end through CM_ATTEN_CHAR.IND. After the vehicle end receives CM_ATTEN_CHAR.IND from the pile end, it informs the pile end through CM_ATTEN_CHAR.RSP that it has received the average attenuation value calculated by it. The vehicle end adds up the attenuation values of the 58 carrier groups in CM_ATTEN_PROFILE.IND to calculate the average and the total average attenuation value. If it is within the reasonable range of 25-45 (some piles may not strictly calculate the attenuation according to the standard, and the lower limit can be changed from 25 to 0), it sends the CM_SLAC_MATCH.REQ instruction to request the establishment of an SLAC connection. Because the characteristics of PLC are prone to crosstalk, there are situations where multiple pile ends respond to the vehicle end request. If this happens, the vehicle end will select the pile end with the smallest attenuation to initiate a MATCH request, where the identifier of the pile end is the EVSE MAC parameter in the CM_SLAC_MATCH.REQ instruction.

Establish connection: After the pile end receives the Match request, if the conditions for establishing a connection are met, it sends CM_SLAC_MATCH.CNF to inform the vehicle end that SLAC has been established. At the same time, the pile end provides NID and NMK. The vehicle end uses CM_SET_KEY.REQ to inform the vehicle end PLC of the generated new NID and NMK for subsequent V2G communication.

(3) Optional steps

Validation: When multiple pile ends give attenuation values through CM_ATTEN_CHAR.IND, and the attenuation values are relatively large, it is necessary to select a pile that is physically connected to the vehicle end through Validation (that is, the CP line is connected). The vehicle end broadcasts the command CM_VALIDATE.REQ for the first time, where Result = 1 informs the pile end that the validation process is about to start. The pile end responds through CM_VALIDATE.CNF, where result = Ready indicates that the validation process can be started. After the vehicle end receives the pile end response Ready, the vehicle end sends CM_VALIDATE.REQ again to inform the pile end that the vehicle end will switch BCB within the time specified by the parameter Timer. Then the vehicle side starts to switch S2 to switch BCB and record the number of times. The pile side informs the vehicle side of the number of BCBs it records through the parameter CM_VALIDATE.CNF. If the number of times recorded by the vehicle side is consistent with the number sent by the pile side, it means that the pile side is physically connected to the vehicle side, and the next step can be taken.

PLC power adjustment: This function is to identify that the PLC power of the other end is inappropriate after the Slac connection is established and send a request to the other end to adjust its PLC power. That is, the vehicle side can initiate a request to the pile side to reduce its PLC output power, or the pile side can initiate a request to the vehicle side to reduce its PLC output power.

4. SLAC technical advantages

(1) Ensure communication stability

In the environment of high noise, multipath attenuation and impedance change of power lines, SLAC technology exchanges detection signals, evaluates channel quality (such as signal attenuation, interference strength), and negotiates the best communication frequency and modulation method to ensure the stability and reliability of the PLC connection between the vehicle and the pile, thereby ensuring the stability of the charging process.

(2) Improving charging efficiency

By quickly and accurately establishing a stable communication connection, SLAC technology makes parameter interaction during the charging process more efficient, reduces charging interruptions or delays caused by communication problems, and improves charging efficiency.

(3) Supporting advanced functions

In addition to basic charging information exchange, SLAC technology also opens the door to more advanced functions such as vehicle-to-grid (V2G) for electric vehicles, making electric vehicles not only energy consumers, but also energy storage units and service providers for the power grid.

5. Application scenarios of SLAC technology

(1) DC charging piles

During the DC charging process, IEC 61851-1 standard mode 4 cleverly uses the existing CP (Control Pilot) line to achieve high-level communication (HLC). This innovative measure allows the DC charging protocol defined in the IEC 61851-23 specification to be transmitted through the CP signal line, greatly improving charging efficiency and safety and making the charging process highly intelligent. As a key link, SLAC technology ensures the stable implementation of this high-level communication.

(2) NACS Charging System

NACS (North American Charging Standard) is a charging standard that Tesla has published for free and open source. Its breakthrough in high-level digital communication is particularly noteworthy. Unlike the traditional single physical communication line design, NACS adopts power line communication (PLC) technology, especially in the use of HomePlug GreenPHY as the data link layer protocol. In the specific implementation, the CP signal circuit on the charging pile and the vehicle is embedded with a modem, and the high-frequency signal modulated by OFDM (orthogonal frequency division multiplexing) is coupled to the CP signal line to achieve efficient data transmission. In this process, SLAC technology ensures the stability and reliability of communication. Even without adding additional communication pins, it can achieve an amazing communication rate of 10 Mbit/s, greatly improving the speed and quality of information exchange during DC charging.

As a key technology in the PLC communication of the charging system

6. Conclusion

As a key technology in the PLC communication of the charging system, SLAC technology ensures the stability and reliability of communication between electric vehicles and charging piles through its unique working principle and process, improves charging efficiency, and supports the realization of advanced functions.

Update cookies preferences