Last week, I troubleshooted a DC fast charging pile. The indicator light wasn’t on, and the charging gun wasn’t responding. Upon removing the back cover, I found two black relays with bulging casings and badly burned contacts. After replacing them, charging returned to normal.

A relay, simply put, is an “automatic switch” that uses low-voltage, low-current control to control high-voltage, high-current. Its core components are an electromagnet, a swingable armature, and two pairs of contacts (normally open and normally closed). When the low-voltage coil is energized, the electromagnet generates attraction, pulling the armature down and connecting the contacts to the main circuit. When the power is cut off, the spring immediately springs back, breaking the circuit.
In new energy vehicle charging piles, relays are far from optional; they bear multiple safety responsibilities.
After the charging gun is plugged in, the on-board charger and the charging pile controller must first “handshake” via signal lines to confirm that the voltage, current, and insulation status are all normal before sending an excitation signal to the relay coil.

Furthermore, there are many requirements in circuit design. If short-distance wiring is not possible due to the design of the wiring terminals themselves, then copper plates are needed for assistance. Whether it’s short-distance or long-distance wiring, we always add a window to the wiring. This increases the stability of current flow and expands the current path. Furthermore, the parts using relays all involve high-voltage electricity, requiring a reasonable safety clearance between them and low-voltage areas.
Therefore, don’t underestimate this relay hidden in the corner of the charging pile. It is both the executor of current switching and the physical embodiment of multiple protection logics—and both roles directly relate to the safety of you and your vehicle.