In DC charging piles, some accessories are prone to problems due to high-frequency use or electrical characteristics. Today, we have sorted out the three most easily damaged accessories in DC charging piles and the corresponding inspection and replacement methods to help you quickly locate faults and ensure the normal operation of the equipment.
Collect this practical guide quickly to learn about the three accessories that are most likely to “strike” and the inspection methods!
1. Fuse
What is the task of the fuse? Simply put, it is to actively disconnect the circuit when the current is “out of control” to protect the safety of the charging pile and cable. However, it is very “fragile” itself. Once damaged, the charging pile may be “silent” directly!

How to judge whether the fuse is broken?
Appearance inspection: Open the charging pile and see if the fuse has any signs of yellowing or burning. If so, there is a high probability that something is wrong.
Tool test: Use a multimeter to test continuity. If it is connected, it means it is good. If it is not connected, it means it has been sacrificed.
Reminder for replacement
When replacing the fuse, remember to match the rated current, voltage value, and size, otherwise, it cannot be installed or it will not work well after installation!
2. High-voltage DC contactor
The contactor is the “circuit switch” of the charging pile, controlling the on and off of the circuit. It is responsible for ensuring the safety and stability of the charging process. If it “goes on strike”, the entire charging pile may not be able to start!

Common problems
Contactor adhesion: The contacts stick together, the switch function fails, and it is directly stuck in the “on state”.
The contactor does not close: the coil is burned out, the circuit cannot be closed, and the charging pile fails.
How to check the contactor problem?
Use a multimeter to measure the auxiliary contacts. If the on-and-off is abnormal or the coil resistance is weird (too small or infinite), it is broken!
If you see the contactor is yellow or burnt, there is no doubt, just replace it.
Replacement precautions
The rated current, voltage, and coil voltage must be matched.
The output terminals (normally open, normally closed) must be matched, don’t install them wrong!
3. Lightning arrester
The last protagonist is the lightning arrester, who can help the charging pile “bear lightning” at critical moments. If there is a lightning strike, the lightning arrester will lead the current to the ground to protect the safety of the charging pile and the user. But it will “suffer” itself, and it may break down after a long time of use.

Common Problems
The charging pile displays the prompt message “Lightning Arrester Failure”.
The appearance of the lightning arrester is damaged, or the prompt label turns red (red = broken, green = normal).
How to confirm whether it is a problem with the lightning arrester?
Check whether the feedback line is detached. If it is detached, it will trigger an alarm. Try to connect it back!
If the feedback line is fine, you can unplug the feedback terminal, and then short-circuit the two wires according to the wiring method to see if the fault prompt disappears. If it disappears, it means that the lightning arrester is damaged; if it does not disappear, it may be that the line is broken or the control board has a problem.
Tips for replacing lightning arresters
Remember to match the model and specifications when replacing a new one.
After installation, check whether the wiring of the feedback terminal is secure.
These accessories of the charging pile may seem small, but if there is a problem, the entire device can be shut down. Therefore, regular inspection is very important! Especially fuses, high-voltage DC contactors, and lightning arresters.