What causes AC charging piles to “trip” while charging?

What causes AC charging piles to “trip” while charging? There are several possible reasons:

building AC charging piles

1. Grid Factors

The grid voltage fluctuates significantly, exceeding the operating input voltage range of the on-board charger (OBC), triggering overvoltage or undervoltage protection and preventing automatic recovery.

The cable leading from the secondary side of the 10kW/380V power transformer is too long, creating a “weak grid” effect. The OBC’s control loop parameters cannot adapt to certain weak grid conditions. Loop oscillations cause input current oscillations, triggering the OBC’s input overcurrent protection.

2. Ground Interference

The vehicle body ground and the grid’s PE ground are connected via the PE copper pins on the charging pile’s tip and base. The OBC’s PE ground is connected via the vehicle body ground and the grid’s PE ground. If numerous high-power devices are connected simultaneously to the grid’s PE ground, this ground can be subject to significant noise, often referred to as a “very dirty ground.” This dirty PE ground can significantly interfere with the CP and CC signal detection of the OBC and AC charging station, potentially causing CAN communication errors within the OBC.

Bluesky AC ev charger
Bluesky AC EV charger

3. Problems with the charging head and charging socket connection

Some vehicle sockets and charging heads have an abnormal connection to the power section. After prolonged charging, the local temperature of the vehicle socket can rise, potentially triggering the vehicle socket’s temperature protection, causing the vehicle to automatically stop charging. This problem doesn’t occur in cold weather or short charging times, but only during long, high-temperature charging.

The CC and CP pins on the charging head don’t match the hole structure of the CC and CP pins on the vehicle socket, resulting in poor contact. If the charging head is shaken or the vehicle vibrates, the signal connection is lost, causing the vehicle to automatically stop charging. The length of the CC and CP pins needs to be increased to be compatible with various vehicle sockets.

4. Misoperation of the leakage detection circuit breaker

Misoperation of the leakage protection circuit breaker is a common problem with circuit breaker tripping. Some AC charging stations have an onboard leakage detection circuit, which can also cause inaccurate leakage detection.

5. Human Factors

During charging, someone may press the stop button on the charging station without realizing that this button will terminate charging. During charging, someone may press the S3 switch on the charging gun, causing the vehicle to detect that the CC resistor is in a semi-connected state and automatically stop charging.