When the charging pile meter communication fails, you first need to check whether the equipment is normal. You can check the connection status of the charging pile and the meter to see if there is any looseness or falling off. At the same time, you also need to check the power supply of the charging pile and the meter, and whether there is any fault such as the power switch. Here is how we solve the meter communication failure:
1. When the error light flashes on the DC charger screen, click the alarm message in the lower left corner to view the alarm content.

2. When you see the red meter of the charger flashing, you need to find the key and open the door of the charger to check the device.

3. Check the ammeter of the charger and check the power and signal wires of the ammeter. Check if it is loose, and tighten the wires if they are loose.

4. Then, check the screen to see if the error message disappears. You need to click “Previous” and enter the fault record page again to view it.

5. If the fault persists, you need to observe the indicator light in the lower right corner of the “MIU” motherboard, as shown in the figure below. If the “LEDR6” indicator light on the right is not on, it means that the 485 chip below is broken and you need to replace it.

In short, charging pile meter communication fails can be solved through a variety of methods, but before handling the fault, sufficient preparations must be made, such as understanding the basic principles of the equipment, carefully adjusting the power supply, etc. Only in this way can the effectiveness and safety of troubleshooting be ensured.