What’s inside the charging pile cabinet?

Many people new to charging piles often have one thought when they first open the charging pile cabinet: “Why is there so much stuff inside?”

Cables, copper busbars, circuit breakers, contactors, meters, switching power supplies, main control boards, charging modules… all sorts of components are crammed together, which can look quite messy. It’s easy not to know where to start. Actually, when learning the internal structure of a charging pile, don’t rush to memorize the name of every single component. Instead, break it down into several circuits and look at them.
You can understand this by following this line: Three-phase power input → Main circuit breaker → AC contactor/subsequent control → Subsequent circuit.

Therefore, this line isn’t about memorizing the wiring sequence, but rather helping us establish a basic understanding: Where does the power come from? What protection does it pass through? When is it allowed to continue supplying power?

Internal Learning Route Map of Charging Pile

1. Charging Pile Power Input

After opening the charging pile cabinet door, the most obvious thing is usually several thick cables. These thick wires are the main power input lines of the charging pile. Taking the wiring in the picture as an example, you can see several thick power lines entering the cabinet below, connecting to the corresponding copper busbars and terminal positions.

Common colors can be understood as follows:

Cable colors: Meaning
Yellow A Phase
Green B Phase
Red C Phase
Blue N Line
Yellow-green (two-tone) PE Protective Ground

The AC input of common charging piles can be understood as a three-phase five-wire system:

Three-phase five-wire system: A, B, C, N, PE.

Charging Pile Power Control

2. Charging Pile Power Control

After reviewing the power input, let’s look at the large black box in the diagram.
It is also commonly called:

  • Circuit breaker
  • Main switch
  • Molded case circuit breaker (MCCB)

It is a crucial “main inlet switch” and “protection switch” after the power enters the charging pile. In other words, although the external three-phase power is connected to the charging pile, it doesn’t directly power downstream equipment; it first passes through this main circuit breaker.

 What is it used for?

The main circuit breaker can be understood as having two main functions:

  • Controlling whether the main power supply is delivered to the equipment;
  • Protecting the lines and equipment.
 Controlling the Main Power Supply to the Equipment

The most obvious function of the main circuit breaker is to control whether external power input can continue to be supplied to the charging station.

It can be understood as follows: External power is connected to the charging station, but the circuit breaker is not closed, which is equivalent to “the door not being opened,” meaning power cannot actually be supplied to the equipment.

Therefore, from this perspective, it is acceptable to understand it as a “switch that controls the power input to the charging station.”

However, more accurately, it is not an ordinary switch, but a main circuit switch with protective functions.

Protecting Lines and Equipment

Circuit breakers are not just responsible for “opening” and “closing”; they also provide protection.

When an abnormality occurs in a line or equipment, the circuit breaker can cut off the power supply, preventing the fault from escalating.
Therefore, it can be simply understood as: Under normal conditions, it is responsible for supplying power; under abnormal conditions, it is responsible for cutting off the power supply and protecting the equipment.

This is also one of the biggest differences between circuit breakers and ordinary switches.

3. AC Contactor

What is the role of an AC contactor in a charging station?
  • Taking a DC charging station as an example, if an AC contactor is configured on the AC input side, it can generally be understood as follows:
  • When the charging station’s self-test is normal, and the control system allows it, the AC contactor engages, and three-phase AC power continues to be supplied to the charging module.
  • After receiving the AC input, the charging module performs AC/DC rectification and DC/DC regulation, finally outputting the DC voltage and DC required by the vehicle.

Function Schematic of AC Contactor

How does an AC contactor work?

An AC contactor can be divided into two parts:

  • The first part is the coil.
  • The coil is the control part, and the current is relatively small. The main control board generally doesn’t directly allow large currents to flow through its own board; instead, it controls the contactor coil through relays, intermediate relays, or drive circuits.
  • The second part is the main contacts.
  • The main contacts are the power part, responsible for connecting or disconnecting the three-phase AC main circuit, and they carry a relatively large operating current.

AC Contactor Working Principle Diagram

Summary

This section started with the AC input front-end, mainly covering three parts:

  • How three-phase power enters the charging station;
  • What role does the main circuit breaker play in the main circuit?
  • Why can an AC contactor be understood as an automatic control switch?

For beginners, remember this: The circuit breaker is responsible for “whether power can be safely supplied,” while the AC contactor is responsible for “connecting or disconnecting downstream circuits when permitted by the main control system.” In other words, the circuit breaker is more like a protective switch for the main circuit, while the AC contactor is more like an automatic switch controlled by the main control board.